Explore Other Data Centers:

London Data Centers

UK Data Centers: Connecting London and the South East to global markets

Inside the 60+ CenturyLink data centers around the globe, technology becomes more agile, secure and sustainable.

We augment traditional colocation solutions with a comprehensive hybrid suite of managed services and cloud, so companies can grow without barriers or penalties.

CenturyLink's portfolio of 5 UK Data Centers consists of campuses in London Docklands, Slough, and Reading, interconnected by direct low-latency fibre routes. The two London Data Centers provide proximity to key financial trading and foreign exchange platforms, as well as providing hosting facilities to London's growing legal and professional services sector. The Slough and Reading facilities are ideally situated for the Hi Tech sector located along the M4 corridor and the geographical distribution of our secure UK Data Centers make CenturyLink an intelligent choice for clients seeking fully resilient dual data center solutions and disaster recovery services.

Announcements

Take a Virtual Tour of our LO5 Data Center

Data Centers

London Data Center Locations

Locations

LO1: Slough, UK

Space: 69,539 sf   Power: 13.5 MW

Tech Specs

LO1: Slough     Space: 69,539 sf     Power: 13.5 MW

Real Estate Summary

  • Located near London Heathrow International Airport; 15 minutes from London
  • Two story building
  • Total building interior (sf) = 69,539
  • Raised floor (mm) = 800

Electrical Summary

  • Southern Electric provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 13.5 MW
  • Minimum one fuel replenishing company

Fire Detection and Suppression Summary

  • VESDA provides early warning detection

Mechanical Summary

  • Cooling system configuration = N +1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

LO3: London, UK

Space: 34,850 sf   Power: 1.5 MW

Tech Specs

LO3: London     Space: 34,850 sf     Power: 1.5 MW

Real Estate Summary

  • Located near London City and Heathrow Airports; 20 and 50 minute drive from London
  • Two story building
  • Total building interior (sf) = 34,850
  • Raised floor (mm)=600

Electrical Summary

  • Southern Electric provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 1.5 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • FM200

Mechanical Summary

  • Cooling system configuration = N+1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

LO4: London, UK

Space:  14,488 sf   Power: 7 MW

Tech Specs

LO4: London     Space: 14,488 sf     Power: 7 MW

Real Estate Summary

  • Located near London City and Heathrow Airports; 20 and 50 minutes from London
  • Eight story building
  • Total building interior (sf) = 14,488
  • Raised floor (mm) = 400

Electrical Summary

  • UKPN provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 7 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • FM 200

Mechanical Summary

  • Cooling system configuration = N+1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

LO5: Slough, UK

Space: 110,864 sf   Power: 13.5 MW

Tech Specs

LO5: Slough     Space: 110,864     Power: 13.5 MW

Real Estate Summary

  • Located near London Heathrow International Airport; 15 minutes from London
  • Two story building
  • Total building interior (sf) = 110,864
  • Raised floor (mm) = 800

Electrical Summary

  • Southern Electric provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 13.5 MW
  • Minimum one fuel replenishing company

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • FM 200

Mechanical Summary

  • Cooling system configuration = N +1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

LO6: Reading, UK

Space: 308,405 sf   Power: 6 MW

Tech Specs

LO6: Reading     Space: 308,405 sf     Power: 6 MW

Real Estate Summary

  • Located near London Heathrow International Airport; 15 minutes from London
  • Two story building
  • Total building interior (sf) = 308,405
  • Raised floor (mm) = 600 and 800

Electrical Summary

  • Southern Electric provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 6 MW
  • Minimum one fuel replenishing company

Fire Detection and Suppression Summary

  • VESDA provides early warning detection

Mechanical Summary

  • Cooling system configuration = N +1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

More Locations

Over 60 Data Center Locations Worldwide

Latest from the EpiCenter Blog

Gartner Data Center Conference 2016 – Unleashing the Power

David Murphy | December 21,2016

You’ve most likely heard the phrase “What happens in Vegas stays in Las Vegas.” Though that may be the case in some instances, CenturyLink’s participation in the Gartner Data Center, Infrastructure & Operations Management Conference in Las Vegas included too … Read more…→ The post Gartner Data Center Conference 2016 – Unleashing the Power appeared first on CenturyLink EpiCenter Blog.

Data Center Infrastructure Management: Sharing Best Practices & Lessons Learned

Kelly Sullivan | December 09,2016

Data center infrastructure management (DCIM) is increasingly being utilized by companies to convert the promise of software-defined IT into value. In fact, the DCIM market is expected to grow to $2.81 billion by 2020. By integrating IT and data center … Read more…→ The post Data Center Infrastructure Management: Sharing Best Practices & Lessons Learned appeared first on CenturyLink EpiCenter Blog.

Disaster Recovery Planning: Preparing for Winter Weather

Chip Freund | November 30,2016

The arrival of winter means many things: family gatherings, cozy fires and warm sweaters and scarves. It also means cold weather, fewer daylight hours, the flu season and travel hazards including bitter cold and snowy and icy roads. In the … Read more…→ The post Disaster Recovery Planning: Preparing for Winter Weather appeared first on CenturyLink EpiCenter Blog.

CenturyLink
Business
@CenturyLink ENT

Resources

Get Started with Featured Resources and Tools

Get Started
Request Consultation

Request Consultation

Call Us

Call Us

SALES: 800.784.2105
SUPPORT: 888.638.6771

Get Connected. See What's Next for Business.