New York & New Jersey Data Centers

Commitment to Compliance

CenturyLink is dedicated to continuously improving and maintaining compliance and standards that are critical to customers.

Ultra-Low Latency Colocation, Proximity Hosting and Network Connectivity

Throughout the 60+ CenturyLink data centers around the globe, fast-moving technology greatly impacts the economy.

Our six New York/New Jersey data centers offer ultra-low latency colocation, proximity hosting and network connectivity to key financial markets venues and trading participants. A dedicated Financial Services sales and support team within each data center manages every component of data with powerful cross connects and financial grade multi-tier security measures. As both a network and hosting provider, CenturyLink provides full network and data center uptime SLAs to meet client needs. The strategically located New York/New Jersey data centers support:

  • One of the top three major US equities exchanges' matching engines
  • Matching engines for three of the five largest US equity dark pools, representing approximately 47% of average daily volume traded in US equities dark pools
  • Connectivity to all key U.S. markets < 200 microseconds (one way latency)
  • A broad range of alternative trading venues and solutions providers, covering multiple asset classes
  • All of Fortune's top 14 Securities Firms, 10 of Fortune's top 13 Diversified Financials, and 10 of Fortune's top 17 Financial Data Services

 

 

 

Announcements

Take a Virtual Tour of our CH3 Data Center

Data Centers

NY & NJ Data Center Locations

Locations

NJ1: Jersey City, NJ

Space: 74,222 s   Power: 3.4 MW

Tech Specs

NJ1: Jersey City     Space: 74,222 sf     Power: 3.4 MW

Real Estate Summary

  • Located near International Airport; 15 minutes from Manhattan, NY
  • Ten story building
  • Total building interior (sf) = 74,222
  • Raised floor (inches) = 12

Electrical Summary

  • PSE&G provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N+1
  • Total Power Capacity = 3.4 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • FM200

Mechanical Summary

  • Cooling system configuration = N +1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

NJ2: Weehawken, NJ

Space: 223,022 sf   Power: 16MW

Tech Specs

NJ2: Weehawken     Space: 223,022 sf     Power: 16 MW

Real Estate Summary

  • Located near Newark International Airport; 15 minutes from Manhattan, NY
  • Four story building
  • Total building interior(sf) = 223,022
  • Raised floor (inches) = 12

Electrical Summary

  • PSE&G provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N+1
  • Total Power Capacity = 16 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • FM200

Mechanical Summary

  • Cooling system configuration = N+1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

NJ2X: Weehawken, NJ

Space: 209,237 sf   Power: 12 MW

Tech Specs

NJ2X: Weehawken     Space: 209,237     Power: 12 MW

Real Estate Summary

  • Located near Newark International Airport; 15 minutes from Manhattan, NY
  • Five story building
  • Total building interior (sf) = 209,237
  • Raised floor (inches) = 24

Electrical Summary

  • PSE&G provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N+1
  • Total Power Capacity = 12 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N+1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

NJ3: Piscataway, NJ

Space: 134,450 sf   Power: 12 MW

Tech Specs

NJ3: Pisataway     Space: 134,450 s     Power: 12 MW

Real Estate Summary

  • Located near Newark International Airport; 15 minutes from Manhattan, NY
  • Three story building
  • Total building interior (sf) = 134,450
  • Raised floor (inches) = 30

Electrical Summary

  • PSE&G provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N+1
  • Total Power Capacity = 12 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N+20%
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

NJ4: Piscataway, NJ

Space: 83,466 sf   Power: 6 MW

Tech Specs

NJ4: Piscataway     Space: 83,466 sf     Power: 6 MW

Real Estate Summary

  • Located near Newark International Airport; 45 minutes from Piscataway, NJ
  • One story building
  • Total building interior (sf) = 83,466
  • Raised floor (inches) = 36

Electrical Summary

  • PSE&G provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N+1
  • Total Power Capacity = 6 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N+20%
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

NJ5: Piscataway, NJ

Space: 78,000 sf   Power: 5.3 MW

Tech Specs

NJ5: Piscataway     Space: 78,000 sf     Power: 5.3 MW

Real Estate Summary

  • Located near Newark International Airport; 15 minutes from Manhattan, NY
  • Fourteen story building
  • Total building interior (sf) = 78,000
  • Raised floor (inches) = 24

Electrical Summary

  • PSE&G provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N+1
  • Total Power Capacity = 5.3 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N+20%
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

More Locations

Over 60 Data Center Locations Worldwide

Latest from the EpiCenter Blog

Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 2

Nader Hantour | February 23,2017

As I noted in part one of this blog, active-active and active-passive data center architectures are often used in businesses’ disaster recovery and business continuity plans. Without such plans in place, companies may face outages which hurt them financially while … Read more…→ The post Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 2 appeared first on CenturyLink EpiCenter Blog.

Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 1

Nader Hantour | February 21,2017

Companies in multiple industries continue to utilize colocation for their mission-critical IT infrastructure and data due to the scalability, reliability, resiliency and security it provides. It enables them to enjoy increased bandwidth, higher network speed and connectivity, carrier diversity, remote … Read more…→ The post Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 1 appeared first on CenturyLink EpiCenter Blog.

Data Center Connectivity: Continual Improvement

Christian Pedersen | February 20,2017

Companies that utilize colocation need to have access to strong network connectivity, especially with the rapidly increasingly amounts of data prompted by “big data” and the Internet of Things (IoT). This enables them to keep connected with their customers through … Read more…→ The post Data Center Connectivity: Continual Improvement appeared first on CenturyLink EpiCenter Blog.

CenturyLink
Business
@CenturyLink ENT

Resources

Get Started with Featured Resources and Tools

Get Started
Request Consultation

Request Consultation

Call Us

Call Us

SALES: 800.784.2105
SUPPORT: 888.638.6771

Get Connected. See What's Next for Business.