San Jose Data Center

Commitment to Compliance

CenturyLink is dedicated to continuously improving and maintaining compliance and standards that are critical to customers.

Realize the power of a CenturyLink Data Center: Serving the San Jose Region

San Jose has long been a vibrant technology hub and center of innovation.

With world-class data center facilities located in nearby Santa Clara and Sunnyvale, CenturyLink is prepared to meet San Jose's data center needs. Our data centers are expertly designed for optimal flexibility, connectivity, security and power, so San Jose companies are well-positioned for innovation and growth.

Learn how the Santa Clara and Sunnyvale, California data centers can serve your business.

Announcements

Take a Virtual Tour of our CH3 Data Center

Data Centers

San Jose Data Center Locations

Locations

SC4: Santa Clara, CA

Space: 167,932 sf   Power: 8 MW

Tech Specs

SC4: Santa Clara     Space: 167,932 sf     Power: 8 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose, 35 minutes from San Francisco, CA
  • Two story building
  • Total building interior (sf) = 167,932
  • Raised floor (inches) = 12

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 8 MW
  • Minimum two fuel replenishing company

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N +1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SC5: Santa Clara, CA

Space: 103,940 sf   Power: 8 MW

Tech Specs

SC5: Santa Clara     Space: 103,940 sf     Power: 8 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose, 35 minutes from San Francisco, CA
  • One story building
  • Total building interior (sf) = 103,940
  • Raised floor (inches) = 18

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 8 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SC8: Santa Clara, CA

Space: 90,139 sf   Power: 10 MW

Tech Specs

SC8: Santa Clara     Space: 90,139 sf     Power: 10 MW

Real Estate Summary

  • Located near San Jose Airport; 10 minutes from San Jose, CA
  • One story building
  • Total building interior (sf) = 90,139
  • Raised floor (inches) = 30

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 10 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SC9: Santa Clara, CA

Space: 124,383 sf   Power: 10 MW

Tech Specs

SC9: Santa Clara     Space: 124,383 sf     Power: 10 MW

Real Estate Summary

  • Located near San Jose Airport; 10 minutes from San Jose, CA
  • One story building
  • Total building interior (sf) = 124,383
  • Raised floor (inches) = 36

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 10 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SN1: Sunnyvale, CA

Space: 76,573  sf   Power: 6 MW

Tech Specs

SN1: Sunnyvale     Space: 76,573 sf     Power: 6 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose and 35 minutes from San Francisco, CA
  • One story building
  • Total building interior (sf) = 76,573
  • Raised floor (inches) = 24

Electrical Summary

  • PG&E provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1 + 1
  • Total Power Capacity = 6 MW
  • Minimum one fuel replenishing company

Fire Detection and Suppression Summary

  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SN2: Sunnyvale, CA

Space: 24,000 sf   Power: 2 MW

Tech Specs

SN2: Sunnyvale     Space: 24,000 sf     Power: 2 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose and 35 minutes from San Francisco, CA
  • One story building
  • Total building interior (sf) = 24,000
  • Raised floor (inches) = 18

Electrical Summary

  • PG&E provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = 2N
  • Total Power Capacity = 2 MW
  • Minimum two fuel replenishing companies

Fire Detection and Suppression Summary

  • Pre-Action system utilizes two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

More Locations

Over 60 Data Center Locations Worldwide

Latest from the EpiCenter Blog

Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 2

Nader Hantour | February 23,2017

As I noted in part one of this blog, active-active and active-passive data center architectures are often used in businesses’ disaster recovery and business continuity plans. Without such plans in place, companies may face outages which hurt them financially while … Read more…→ The post Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 2 appeared first on CenturyLink EpiCenter Blog.

Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 1

Nader Hantour | February 21,2017

Companies in multiple industries continue to utilize colocation for their mission-critical IT infrastructure and data due to the scalability, reliability, resiliency and security it provides. It enables them to enjoy increased bandwidth, higher network speed and connectivity, carrier diversity, remote … Read more…→ The post Active-active vs. Active-passive: Which Data Center Architecture has the Advantage for Disaster Recovery? – Part 1 appeared first on CenturyLink EpiCenter Blog.

Data Center Connectivity: Continual Improvement

Christian Pedersen | February 20,2017

Companies that utilize colocation need to have access to strong network connectivity, especially with the rapidly increasingly amounts of data prompted by “big data” and the Internet of Things (IoT). This enables them to keep connected with their customers through … Read more…→ The post Data Center Connectivity: Continual Improvement appeared first on CenturyLink EpiCenter Blog.

CenturyLink
Business
@CenturyLink ENT

Resources

Get Started with Featured Resources and Tools

Get Started
Request Consultation

Request Consultation

Call Us

Call Us

SALES: 800.784.2105
SUPPORT: 888.638.6771

Get Connected. See What's Next for Business.