Full Test

Client Self Test provides Wholesale customers with the ability to perform testing on their DS1 circuits. A CEMR-MTG customer with valid CEMR-MTG credentials is able to log in and run a Full Test as if CenturyLink were conducting the test via Test Expert.

Note: A customer who runs a Full Test could experience circuit down time. A pop-up message will read: “Warning this is an intrusive test. The circuit will be taken out of service for the duration of the test.”

The test provides all of the information CenturyLink is able to collect via Test Expert.

Full Test Responses

Test Expert Results

Summary Code

Text Response

No test access available

NTA

No test access available – Please open a ticket.

DS1 PM's clean

CLN

DS1 PM's Clean

Test OK

TOK

No trouble found on the circuit

Errors in CenturyLink Network (line)

ERL

Errors in the CenturyLink network – Please open a ticket

Errors Not Isolated (path)

ERP

Errors detected, not isolated – Please review before opening a ticket

HDSL errors detected

TQF

Trouble Found in CenturyLink network field – Please open a ticket.

Trouble to the office repeater

TQO

Trouble Found in CenturyLink network office - Please open a ticket

Inconclusive results

INC

Unspecified failure took place – Please open a ticket

Errors to NIU or Field devices

TQF

Trouble Found in CenturyLink network – NIU or Repeaters – Please open a ticket

CPE

CPE

Clean to NIU, taking errors to the CSU – Please contact your end user and isolate trouble further

Alarm Red

ALR

 RED ALARM detected.  No further trouble found.

Alarm Yellow

ALY

YELLOW ALARM detected.  No further trouble found. 

OOS, CenturyLink network TOK

QOK

Circuit is out of service or taking errors, CenturyLink network and equipment is test OK – Further isolation needed outside of CenturyLink